Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Users
  • Groups
Skins
  • Light
  • Cerulean
  • Cosmo
  • Flatly
  • Journal
  • Litera
  • Lumen
  • Lux
  • Materia
  • Minty
  • Morph
  • Pulse
  • Sandstone
  • Simplex
  • Sketchy
  • Spacelab
  • United
  • Yeti
  • Zephyr
  • Dark
  • Cyborg
  • Darkly
  • Quartz
  • Slate
  • Solar
  • Superhero
  • Vapor

  • Default (No Skin)
  • No Skin
Collapse

The New Coffee Room

  1. TNCR
  2. General Discussion
  3. Kinda Geeky - the story of the pulse oximeter

Kinda Geeky - the story of the pulse oximeter

Scheduled Pinned Locked Moved General Discussion
16 Posts 6 Posters 140 Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • George KG Offline
    George KG Offline
    George K
    wrote on last edited by
    #6

    Oh, at 0:30 he says, "The oxygen saturation is effectively how much oxygen in your blood."

    That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

    If you're anemic as hell, you won't do well, because you don't have the Hb.

    "Now look here, you Baltic gas passer... " - Mik, 6/14/08

    The saying, "Lite is just one damn thing after another," is a gross understatement. The damn things overlap.

    KlausK 1 Reply Last reply
    • George KG George K

      Oh, at 0:30 he says, "The oxygen saturation is effectively how much oxygen in your blood."

      That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

      If you're anemic as hell, you won't do well, because you don't have the Hb.

      KlausK Offline
      KlausK Offline
      Klaus
      wrote on last edited by
      #7

      @George-K said in Kinda Geeky - the story of the pulse oximeter:

      That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

      But the pulse oximeter would show the same 100% in both cases, right?

      So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

      George KG 1 Reply Last reply
      • KlausK Klaus

        @George-K said in Kinda Geeky - the story of the pulse oximeter:

        That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

        But the pulse oximeter would show the same 100% in both cases, right?

        So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

        George KG Offline
        George KG Offline
        George K
        wrote on last edited by George K
        #8

        @Klaus said in Kinda Geeky - the story of the pulse oximeter:

        @George-K said in Kinda Geeky - the story of the pulse oximeter:

        That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

        But the pulse oximeter would show the same 100% in both cases, right?

        So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

        Yes.

        Well, that plus a small amount of dissolved oxygen in the blood not bound to hemoglobin. Very small.

        "Now look here, you Baltic gas passer... " - Mik, 6/14/08

        The saying, "Lite is just one damn thing after another," is a gross understatement. The damn things overlap.

        KlausK 1 Reply Last reply
        • George KG George K

          @Klaus said in Kinda Geeky - the story of the pulse oximeter:

          @George-K said in Kinda Geeky - the story of the pulse oximeter:

          That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

          But the pulse oximeter would show the same 100% in both cases, right?

          So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

          Yes.

          Well, that plus a small amount of dissolved oxygen in the blood not bound to hemoglobin. Very small.

          KlausK Offline
          KlausK Offline
          Klaus
          wrote on last edited by
          #9

          @George-K said in Kinda Geeky - the story of the pulse oximeter:

          @Klaus said in Kinda Geeky - the story of the pulse oximeter:

          @George-K said in Kinda Geeky - the story of the pulse oximeter:

          That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

          But the pulse oximeter would show the same 100% in both cases, right?

          So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

          Yes.

          Well, that plus a small amount of dissolved oxygen in the blood not bound to hemoglobin. Very small.

          I wonder, though, how it is possible that both saturation and hemoglobin level can be measured by means of light reflection.

          George KG 1 Reply Last reply
          • KlausK Klaus

            @George-K said in Kinda Geeky - the story of the pulse oximeter:

            @Klaus said in Kinda Geeky - the story of the pulse oximeter:

            @George-K said in Kinda Geeky - the story of the pulse oximeter:

            That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

            But the pulse oximeter would show the same 100% in both cases, right?

            So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

            Yes.

            Well, that plus a small amount of dissolved oxygen in the blood not bound to hemoglobin. Very small.

            I wonder, though, how it is possible that both saturation and hemoglobin level can be measured by means of light reflection.

            George KG Offline
            George KG Offline
            George K
            wrote on last edited by
            #10

            @Klaus said in Kinda Geeky - the story of the pulse oximeter:

            @George-K said in Kinda Geeky - the story of the pulse oximeter:

            @Klaus said in Kinda Geeky - the story of the pulse oximeter:

            @George-K said in Kinda Geeky - the story of the pulse oximeter:

            That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

            But the pulse oximeter would show the same 100% in both cases, right?

            So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

            Yes.

            Well, that plus a small amount of dissolved oxygen in the blood not bound to hemoglobin. Very small.

            I wonder, though, how it is possible that both saturation and hemoglobin level can be measured by means of light reflection.

            Pulse oximeter doesn't measure hemoglobin. It measures the absorption of red and near infra-red light by oxyhemoglobin and deoxyhemoglbin. The ratio is the % saturation.

            Looking around for how Ember measures Hb is not helpful.

            "Now look here, you Baltic gas passer... " - Mik, 6/14/08

            The saying, "Lite is just one damn thing after another," is a gross understatement. The damn things overlap.

            KlausK 1 Reply Last reply
            • George KG George K

              @Klaus said in Kinda Geeky - the story of the pulse oximeter:

              @George-K said in Kinda Geeky - the story of the pulse oximeter:

              @Klaus said in Kinda Geeky - the story of the pulse oximeter:

              @George-K said in Kinda Geeky - the story of the pulse oximeter:

              That's completely false. It is the percentage of hemoglobin that is carrying oxygen. If your hemoglobin is 7, and 100% saturated, you're carrying half the oxygen of someone with a 100% saturation with a hemoglobin of 14.

              But the pulse oximeter would show the same 100% in both cases, right?

              So, the total oxygen content in the blood stream would proportional to the hemoglobin value multiplied with the saturation, right?

              Yes.

              Well, that plus a small amount of dissolved oxygen in the blood not bound to hemoglobin. Very small.

              I wonder, though, how it is possible that both saturation and hemoglobin level can be measured by means of light reflection.

              Pulse oximeter doesn't measure hemoglobin. It measures the absorption of red and near infra-red light by oxyhemoglobin and deoxyhemoglbin. The ratio is the % saturation.

              Looking around for how Ember measures Hb is not helpful.

              KlausK Offline
              KlausK Offline
              Klaus
              wrote on last edited by
              #11

              @George-K said in Kinda Geeky - the story of the pulse oximeter:

              Looking around for how Ember measures Hb is not helpful.

              They do have some information on how it works and link to various studies that supposedly illustrate that this actually works.

              George KG 1 Reply Last reply
              • KlausK Klaus

                @George-K said in Kinda Geeky - the story of the pulse oximeter:

                Looking around for how Ember measures Hb is not helpful.

                They do have some information on how it works and link to various studies that supposedly illustrate that this actually works.

                George KG Offline
                George KG Offline
                George K
                wrote on last edited by
                #12

                @Klaus said in Kinda Geeky - the story of the pulse oximeter:

                @George-K said in Kinda Geeky - the story of the pulse oximeter:

                Looking around for how Ember measures Hb is not helpful.

                They do have some information on how it works

                Screen Shot 2022-06-29 at 6.54.41 AM.png

                And_then_a_miracle_happens_cartoon.jpg

                "Now look here, you Baltic gas passer... " - Mik, 6/14/08

                The saying, "Lite is just one damn thing after another," is a gross understatement. The damn things overlap.

                KlausK 1 Reply Last reply
                • George KG George K

                  @Klaus said in Kinda Geeky - the story of the pulse oximeter:

                  @George-K said in Kinda Geeky - the story of the pulse oximeter:

                  Looking around for how Ember measures Hb is not helpful.

                  They do have some information on how it works

                  Screen Shot 2022-06-29 at 6.54.41 AM.png

                  And_then_a_miracle_happens_cartoon.jpg

                  KlausK Offline
                  KlausK Offline
                  Klaus
                  wrote on last edited by Klaus
                  #13

                  @George-K From what I understand, their key idea - compared to a normal pulse oximeter - is to use light at many different wavelengths, and supposedly by comparing how much light is reflected at each wavelength they can infer the hemoglobin level.

                  Also note that they are quite specific about the Bluetooth standard they are using. I'm glad that they don't use the outdated BT 3.0 and opted for BT 4.0. In any case, that seems to be more relevant than pesky details about how this "works".

                  George KG 1 Reply Last reply
                  • KlausK Klaus

                    @George-K From what I understand, their key idea - compared to a normal pulse oximeter - is to use light at many different wavelengths, and supposedly by comparing how much light is reflected at each wavelength they can infer the hemoglobin level.

                    Also note that they are quite specific about the Bluetooth standard they are using. I'm glad that they don't use the outdated BT 3.0 and opted for BT 4.0. In any case, that seems to be more relevant than pesky details about how this "works".

                    George KG Offline
                    George KG Offline
                    George K
                    wrote on last edited by
                    #14

                    @Klaus

                    image.jpeg

                    "Now look here, you Baltic gas passer... " - Mik, 6/14/08

                    The saying, "Lite is just one damn thing after another," is a gross understatement. The damn things overlap.

                    B 1 Reply Last reply
                    • George KG George K

                      @Klaus

                      image.jpeg

                      B Offline
                      B Offline
                      blondie
                      wrote on last edited by
                      #15

                      I remember being a young nurse working on a 40 bed pediatric unit in a big general hospital, sitting on an equipment committee. It was during the 1980s & we’d borrowed one to try out. We had no cardiac monitors on our unit. 02 saturation monitors were really expensive back then. ?Were they Nelcor? Thousands of $$$$. I recall listening to adult medicine people questioning how useful they’d actually be on babies and kids who wiggled & squirmed with their pudgy fingers & toes. Anyway, our unit got 1. It was in continuous use. To me, it ranked up there on the pediatric innovation scale alongside the buretrol, IV pumps & BP machines (thermometers too, but I recall doing a lot of axilla & rectal temps on kids back then). But with O2 sat monitoring, for little ones on a general ward, it meant too we could continually monitor pulse rate .. & that meant loads when little ones were sleeping.

                      Later, I remember the 1990s, working in peds and neonatal ICUs, learning, seeing limitations of O2 sat monitoring with certain patients, certain situations, conditions, ….where when drawing blood gases, 02 saturation values were expected to differ .. like of course they did … we had our eyes and experience to tell us why …. Using our brains, we “looked at the patient before we looked at the monitor”. George, remember that expression?

                      like, my gosh, George, .. “Systemic Racism” in O2 Saturation Monitoring”? .. it’s a thing, ya know. So, tell me if/when when such a race-corrected O2 Sat Monitor will be invented & sold cheap on Amazon?

                      B 1 Reply Last reply
                      • B blondie

                        I remember being a young nurse working on a 40 bed pediatric unit in a big general hospital, sitting on an equipment committee. It was during the 1980s & we’d borrowed one to try out. We had no cardiac monitors on our unit. 02 saturation monitors were really expensive back then. ?Were they Nelcor? Thousands of $$$$. I recall listening to adult medicine people questioning how useful they’d actually be on babies and kids who wiggled & squirmed with their pudgy fingers & toes. Anyway, our unit got 1. It was in continuous use. To me, it ranked up there on the pediatric innovation scale alongside the buretrol, IV pumps & BP machines (thermometers too, but I recall doing a lot of axilla & rectal temps on kids back then). But with O2 sat monitoring, for little ones on a general ward, it meant too we could continually monitor pulse rate .. & that meant loads when little ones were sleeping.

                        Later, I remember the 1990s, working in peds and neonatal ICUs, learning, seeing limitations of O2 sat monitoring with certain patients, certain situations, conditions, ….where when drawing blood gases, 02 saturation values were expected to differ .. like of course they did … we had our eyes and experience to tell us why …. Using our brains, we “looked at the patient before we looked at the monitor”. George, remember that expression?

                        like, my gosh, George, .. “Systemic Racism” in O2 Saturation Monitoring”? .. it’s a thing, ya know. So, tell me if/when when such a race-corrected O2 Sat Monitor will be invented & sold cheap on Amazon?

                        B Offline
                        B Offline
                        blondie
                        wrote on last edited by
                        #16

                        Like maybe I’m biased, should acknowledge my race, privilege, or something, but how the heck would a race-corrected 02 sat monitor help in situations of sickle cell, shunting anatomy, the near dead popsicle toes, all that? Like WTF is it with this word “systemic racism” and supposedly educated people?

                        1 Reply Last reply
                        Reply
                        • Reply as topic
                        Log in to reply
                        • Oldest to Newest
                        • Newest to Oldest
                        • Most Votes


                        • Login

                        • Don't have an account? Register

                        • Login or register to search.
                        • First post
                          Last post
                        0
                        • Categories
                        • Recent
                        • Tags
                        • Popular
                        • Users
                        • Groups